Fume cupboards

Description

Stainless or acid-proof steel is used as fume cupboard material to meet the strict requirements of laboratories and hospitals in terms of chemical resistance and hygiene. If necessary the worktop and sink material can also be ceramic.

Fume cupboards are available with straight or sloped front wall. Models with straight wall are well suited for large equipment. Sloped front wall facilitates the sedentary work (see the photo). The standard and additional accessories are listed in the Technical information section under. Cabling and pipe lines are running inside the double structure of rear and side walls. The pool like structure of the worktop makes it easier to keep clean.

In addition to cabinets and drawers fireproof cabinets can also be placed under the work bench for storing of flammable liquids. Cabinets can be connected to the fume cupboard’s ventilation.

Special fume cupboards are available e.g. for radiation therapy units, pathology laboratories and as environments for larger equipment.

For transportation and storage of samples while working there are also ventilated trolleys available.

Product data sheet

Technical information

Models
1010 Fume cupboard straight front wall
1015 Fume cupboard sloped front wall
1015 Standard fume cupboard models: width 1200 mm, 1500 mm and 1800 mm are equipped with exhaust air monitoring and alarm system, and if necessary, with one Broen laboratory faucet and a slope sink

Materials
Stainless steel AISI 304
Acid proof steel AISI 316

Widths
Standard 1200, 1500 and 1800 mm
Special widths 800–3000 mm

Depths
Standard 790 mm
Special depths 600–1400 mm

Heights
Straight front wall 2300 mm
Sloped front wall 2220 mm

Height of the worktop
Standard 700 and 900 mm
Height adjustment range 300 mm (-200 – +100 mm)
Special heights 350–1100 mm

Hauling dimensions
Standard cupboards (width +200 mm) x 900 x 2400 mm
The cupboard can be detached into two parts for easier hauling (not applicable for height adjustable models)

Standards and directives taken into account
EN 14175-2 Fume cupboards
EN 60204-1 Electrical equipment of machines
ISO 12100 Safety of machinery
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
Machinery Directive 2006/42/EU

Certificates
I.F.I. Institut für Industrieaerodynamik GmbH
Type test approval (EN14175-3) for standard fume cupboard models

Accessories included
Lighting 1000 lx, pressure difference gauge, operation switch 0-1-2, signal light, double socket outlet

Accessories
ATEX-protection (inside)
Basins (RST and HST)
Lock of the sash in upper position
Cold section
Connections (data, gas, compressed air)
Ceramic worktop (and sink)
Double socket outlet
Drains (formalin, special waste, water)
Fire proof cabinet
Height adjustment
Light intensity 1000 lx
Painted interior
Pass through hatch
Radiation protection
Scale platform, stone
Shelves
Side walls, glass
Sinks (stainless or acid proof)
Slop sink
Taps (ethanol, formalin, water, water-suction) HEPA-filter
Ventilation connection to cabinets or formalin trolley
Waste bin hole
Waste bin for confidential material
Electric front glass
Automatic closing of the front glass
Bent front glass

Lighting
25 W LED, light intensity on worktop 1000 lx (fume cupboards under 1500 mm)

Ventilation connection
Widths under 1000 mm 1 pc d=160 mm
Widths 1000–2000 mm 2 pcs d=160 mm
Widths over 2000 mm 3 pcs d=160 mm
If necessary connections can be joined together (adds +300 mm to the height)

Exhaust air volume
Nominal air volume 500 m3/h (140 l/s) per meter of fume cupboard width. This results a flow rate of 0,5m/s with 30 cm sash opening and 0,3m/s with full 50 cm sash opening.
Standard fume cupboard 1200mm 600 m3/h
Standard fume cupboard 1500mm 750 m3/h
Standard fume cupboard 1800mm 900 m3/h

Electrical connections
Lighting 230 V, 1N, 50 Hz
Sockets 230 V, 1N, 50 Hz
Separate connection boxes for both on top of the fume cupboard

Connections for water and drain
The size of the connection depends on tap configuration
Water line connection h=2400 mm on top of the cupboard or under the worktop
Water and drain connections
Drain connection according to the sink configuration
Water line connection h=2400 mm on top of the cupboard or under the worktop
Drain connection according to the sink configuration

Gas connections
The size of the connection depends on the socket configuration
Connection point h=2400 mm on top of the cupboard

Control of the ventilation
Standard: signal light, pressure difference gauge and operation switch (0-1-2)
As an option an automatic air volume adjustment device can be installed

Manufacturer
Kavika HealthCare Oy, Mursketie 6, 15860 Hollola
contact@kavikahealthcare.fi, www.kavikahealthcare.fi